BrightSpec
Next Generation MCA Equipment & Software
![Brightspec bMCA-U plug-on base](http://johncaunt.com/wp-content/uploads/2019/04/JCS-MCA-group-2.png)
![Brightspec bMCA-U plug-on base](http://johncaunt.com/wp-content/uploads/2019/04/bMCA-U.png)
Compact, 14 pin digital plug-on Multi-Channel Analysers able to perform tasks such as Pulse Height Analysis (PHA) & Multi Channel Scaling (MCS).
![Image is not available](http://johncaunt.com/wp-content/uploads/2019/04/Bpad.png)
Intelligent, compact Single-Channel Analysers. Unlike traditional designs, this device is fully digitally controlled via USB, no scope or fiddling with screwdrivers.
![Image is not available](http://johncaunt.com/wp-content/uploads/2019/04/Topaz-hr-1.png)
Stand-alone high-resolution MCA for gamma-ray spectrometry. Designed to be used with Hyper Pure Ge (HPGe) detectors, CdZnTL, Si(Li), SDD & PIPS
![Brightspec bMCA-U plug-on base](http://johncaunt.com/wp-content/uploads/2019/04/bMCA-U.png)
bMCA-U
- 14Pin PMT plug
- USB 2.0 connection 1.2 Mb/sec
- PHA & MCS Acquisition modes
- Sampling rate 25 Ms/s, 12-bit
- DSP: 50 Mhz. Trapezoidal shaper
- Detector HV Bias ≤ + 1500 Volts
- Channels: 4096, 32-bits
- Gamma-ray spectrometry
![Brightspec bMCA-U plug-on base](http://johncaunt.com/wp-content/uploads/2019/04/bMCA-U.png)
bMCA-E
- 14Pin PMT plug
- Ethernet 10/100
- PHA & MCS Acquisition modes
- Sampling rate 25 Ms/s, 12-bit
- DSP: 50 Mhz. Trapezoidal shaper
- Detector HV Bias ≤ + 1500 Volts
- Channels: 4096, 32-bits
- Gamma-ray spectrometry
![Brightspec bMCA-U plug-on base](http://johncaunt.com/wp-content/uploads/2019/04/Topaz-hr-1.png)
Topaz-HR
- Stand-alone MCA
- High-speed USB 480 Mb/sec
- PHA, MCS, LIST & TLIST Acquisition modes
- Sampling rate 50 Ms/s, 14-bit
- DSP: 100 Mhz. Trapezoidal shaper
- Detector HV Bias ≤ ± 6000 Volts
- Channels: 16,384, 32-bits
- Gamma and X-ray spectrometry.
- High resolution applications
Topaz SiPM
- Stand-alone MCA
- USB 2.0 connection 1.2 Mb/sec
- PHA & MCS Acquisition modes
- Designed for SiPM
- Low power consumption & low-noise
- Minature -70x45x26mm (LxWxH)
- Channels: 4096, 32-bits
- Gamma-ray spectrometry
![Brightspec bMCA-U plug-on base](http://johncaunt.com/wp-content/uploads/2019/04/Topaz-X-sm.png)
Topaz-X
- Stand-alone MCA
- High-speed USB 480 Mb/sec
- PHA, MCS, LIST & TLIST Acquisition modes
- Sampling rate 50 Ms/s, 14-bit
- DSP: 100 Mhz. Trapezoidal shaper
- Detector HV Bias ≤ ± 6000 Volts
- Channels: 16,384, 32-bits
- X-ray spectrometry, ED XRF, Charge particles
- High resolution applications
![Brightspec bMCA-U plug-on base](http://johncaunt.com/wp-content/uploads/2019/04/Topaz-Pico.png)
Topaz Pico
- Stand-alone MCA
- USB 2.0 connection 1.2 Mb/sec
- PHA & MCS Acquisition modes
- Sampling rate 25 Ms/s, 12-bit
- DSP: 50 Mhz. Trapezoidal shaper
- Detector HV Bias ≤ + 1500 Volts
- Channels: 4096, 32-bits
- Gamma-ray spectrometry
![Brightspec bMCA-U plug-on base](http://johncaunt.com/wp-content/uploads/2019/04/Topaz-Pico.png)
Topaz Pico SiPM
- Stand-alone MCA
- Designed for Scintillators with SiPM
- USB 2.0 connection 1.2 Mb/sec
- PHA & MCS Acquisition modes
- Sampling rate 25 Ms/s, 12-bit
- DSP: 50 Mhz. Trapezoidal shaper
- Detector HV Bias ≤ + 1500 Volts
- Channels: 4096, 32-bits
- Gamma-ray spectrometry
![Gamma Spec Software Gamma Spec Software](http://johncaunt.com/wp-content/uploads/2019/04/Software-1.png)
![Gamma Spec Software Gamma Spec Software](http://johncaunt.com/wp-content/uploads/2019/04/Software-1.png)
![Gamma Spec software](http://johncaunt.com/wp-content/uploads/2019/04/bGamma-2.jpg)
The new bGamma software is a general purpose, comprehensive and extensive application package for gamma-ray spectrum analysis and radionuclide identification and quantification.
![Gamma Spec software](http://johncaunt.com/wp-content/uploads/2019/04/bbGamma-1.jpg)
Modern, comprehensive, powerful graphical user interface (GUI), with flexible and complete dash-board.
![Image is not available](http://johncaunt.com/wp-content/uploads/2019/04/bGamma-3.jpg)
bGamma incorporates the entire radionuclide decay emissions database. All nuclides data available at any instance of the spectrum analysis and/or data visualization. The nuclide decay data are taken from NuDat, which is produced, certified and maintained by the International Nuclear Data Committee.
![](http://smartslider3.com/wp-content/uploads/slider149/content82.jpg)
![Image is not available](http://johncaunt.com/wp-content/uploads/2019/04/AWE.png)
![Image is not available](http://johncaunt.com/wp-content/uploads/2019/04/Sellafield-logo.png)
![Image is not available](http://johncaunt.com/wp-content/uploads/2019/04/NNL-logo.png)
![Image is not available](http://johncaunt.com/wp-content/uploads/2019/04/cern-logo.png)
![Image is not available](http://johncaunt.com/wp-content/uploads/2019/04/MinistryOfDefence.png)
![Image is not available](http://johncaunt.com/wp-content/uploads/2019/04/NHS-logo.png)